1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

If the MIDI channel for CLICK 1, CLICK 2 or the SYNC POP is set to the same
MIDI channel as VIDEO, the MIDI note numbers for that function will be set to the

default note numbers.


(All factory settings can be recalled if the "SETUP" button is hold for three seconds

when turning on the power. All custom settings will be erased.)


NOTE:If visual events are to be controlled by MIDI note on commands make sure

that the NOTE/SYSEX setting is correct.


MIDI VELOCITY: OFF/ON (Default VEL OFF)

Press the SETUP button once and the NEXT button until either the VEL. OFF or

VEL. ON LED is lit. Use the SET button to chose the desired function.


VIDEO FORMAT: PAL / NTSC (Default NTSC)

If no video signal is input, ProCue 1m1 will provide either PAL or NTSC black
generation. Press the SETUP button until either the PAL or NTSC LED is lit. Use the

SET button to choose the desired black generation.
Note: If a video signal is input the black generation will be locked to the same video

format as the incoming and can't be changed in SETUP.


SCREEN FORMAT: 4:3 / 16:9(Default 4:3)

Press the SETUP button once and the NEXT button until either the 4:3 or the 16:9

LED is lit. Use the SET button to shift the setting.

VIDEO EVENT CONTROL:NOTE/ SYSEX. (Default is SYSEX)
The Video event generator in ProCue 1m1 can be controlled with two kinds of MIDI

commands.

1)MIDI NOTE ON COMMANDS

If Visual events should be controlled by a MIDI sequencer or a MIDI keyboard,

"NOTE" or "SYSEX+NOTE" mode should be chosen. (See also figure 3. Page 8)

2) MIDI SYSEX MESSAGES

If visual events should be triggered by the Auricle® or Cue® software the
"SYSEX" or "SYSEX+NOTE" mode should be chosen.


Press the SETUP button once and the NEXT button until either the "NOTE" LED or

the "SYSEX" LED or both are lit. Use the SET button to choose one of the following

settings: